水矢量技术在冷却塔的工业应用分析
2020-02-25马明毛开清谷峰彭庆永
马明 毛开清 谷峰 彭庆永
摘 要:冷却塔的作用是将携带的冷却水在冷却塔内与空气进行热湿交换,空气带着冷却水的废热送入大气散发,使冷却水水温下降,将宝贵的水资源循环利用。传统冷却塔主要依靠电力来驱动风扇,产生大量的电费,而这部分费用在企业成本支出中比例占比较大,给企业造成了很大的压力。文章所阐述的水矢量技术是一种新型的科研技术,其在冷却塔上的工业应用,刷新了传统式的冷却行业模式。对于业界冷却塔的设计应用具有很好的参考意义。关键词:水矢量;冷却塔;节水中图分类号:TU279.7+41 文献标识码:A 文章编号:1671-7988(2020)02-142-03
Abstract: The function of the cooling tower is to exchange heat and humidity with the air in the cooling tower. The air with the waste heat of the cooling water is sent to the atmosphere for emission, which makes the cooling water temperature drop and recycles the valuable water resources. The traditional cooling tower mainly relies on the power to drive the fan, which results in a large amount of electricity charges, which account for a large proportion of the cost of the enterprise, causing great pressure on the enterprise. The water vector technology described in this paper is a new type of scientific research technology. Its industrial application on the cooling tower refreshes the traditional cooling industry mode. It has a good reference for the design and application of cooling tower in the industry.Keywords: Water vector; Cooling tower; Water savingCLC NO.: TU279.7+41 Document Code: A Article ID: 1671-7988(2020)02-142-03
引言
傳统冷却塔多采用机械通风的方式对循环水进行冷却降温,根据流量的大小,配置不同规格的电机。冷却塔的冷却系统不管实际流量大小如何,风机都需要电机驱动旋转,以达到循环水降温的目的。同时,传统的冷却塔为保证冷却系统能够起到足够冷却,会在常规指标的基础上放大15%左右的余量,无形中增加了电能的耗量,不仅造成能源的浪费,还给企业增加了成本。
1 冷却塔系统概述
1.1 冷却塔原理及构造
冷却塔主要以水作为循环介质进行冷却,它是从水系统中吸收热量排至空气中,以达到降低水温的一种装置。利用水与空气流动接触后冷热交换产生蒸汽,再由蒸汽挥发带走热量达到蒸发散热、对流传热和辐射传热等来散去工业上或制冷设备中产生的余热来降低水温的蒸发散热装置,保证整套系统的正常运行,装置一般为桶状或方形状。……