摘  要  建立了分散固相萃取(d-SPE)-高效液相色谱(HPLC)分析测定黄瓜中喹啉铜残留量的方法。样品采用乙腈和0.1 mol/L盐酸混合溶液提取,C18填料净化,高效液相色谱仪分离,紫外检测器检测。其色谱条件为:色谱柱SunFireC18(4.6×150 mm,5 ?m),流动相为十二烷基硫酸钠磷酸盐缓冲液乙腈(65∶35)体系,流速0.6 mL/min,检测波长250 nm。结果表明:在0.02、0.2、2 mg/kg三个添加水平下,喹啉铜回收率在92.3%~107.7%之间,相对标准偏差(RSD)在2.0%~7.7%之间。该方法操作简单、灵敏度和准确度高,能够用于黄瓜中喹啉铜的残留分析。

关键词  黄瓜;喹啉铜;分散固相萃取;高效液相色谱法

中图分类号  X839.2      文献标识码  A

Abstract  A high performance liquid chromatography (HPLC) coupled with the dispersive solid phase extraction (d-SPE) method for the determination of oxine-copper residue in cucumber was established. The sample was extracted by acetonitrile and hydrochloric acid (0.1 mol/L). The extract was purified by C18. The analysis was carried out by phosphate buffer saline (PBS) and sodium dodecyl sulfate (SDS) -acetonitrile (65∶35) at a flow rate of 0.6 mL/min on SunFireC18 (4.6×150 mm, 5 ?m) column, and detected by HPLC with UV detector at a ultraviolet absorption wavelength of 250 nm. The recovery was in 92.3%107.7% with relative standard deviation (RSD) of 2.0%7.7% at spiked levels of 0.02, 0.2 and 2 mg/kg. The method is simple, sensitive and accurate, and could be used in the determination of oxine-copper residue in cucumber.

Keywords  Cucumis sativus L.; oxine-copper; dispersive solid phase extraction; high performance liquid chromatography

DOI  10.3969/j.issn.1000-2561.2019.07.029

8-羟基喹啉铜(oxine-copper,简称为喹啉铜)是黄瓜上常用的一种广谱、高效、低毒的有机铜螯合物杀菌剂,喷施后在植物表面形成药膜,释放杀菌的铜离子,可有效抑制病菌的萌发和侵入,对梨、苹果、黄瓜、西瓜和番茄等作物真菌和细菌性病害起到预防和治疗作用[1-2]。喹啉铜的使用虽然可以减少农业病虫害,但过量使用会造成农药残留,通过食物被人体吸收,铜在人体内达到一定浓度时可形成羟基自由基的催化剂,造成人体DNA的损伤,诱发癌细胞的生成[3],世界衛生组织国际癌症研究机构将喹啉铜归为第三类致癌物质[4]。因此建立准确快速的喹啉铜残留检测方法,是评价蔬菜水果中喹啉铜残留风险和监管农产品市场的必要手段。喹啉铜的传统测定方法有氧化-还原滴定法[2],该方法是通过目测颜色变化确定终点,准确度不高,需要大量人力及分析时间,不适于大批量样品的检测。……

登录APP查看全文