基于非线性动力学建模的PTSC滤波与无功补偿系统研究
2019-08-27骆厚继
骆厚继
摘 要:根据煤矿集团变电站供电模式的不同,可知大功率直流设备与变频设备的使用均存在无功和谐波问题的影响,极易使电网运行质量受到干扰,使煤矿开采存在风险。而为了解决以上问题,必须基于非线性动力学建模系统明确无功与谐波影响的确切位置与参数,落实模拟实验,而后再提供对应的滤波装置与无功补偿系统,分辨是否能够遏制此类问题继续出现,才能使此类变电站问题得以有效解决。
关键词:非线性动力学;PTSC滤波;无功补偿;系统设计
中图分类号:TM714.3 文献标志码:A 文章編号:2095-2945(2019)22-0011-03
Abstract: According to the different power supply modes of substation in a coal mine group, it is known that the use of high-power DC equipment and frequency conversion equipment have the influence of reactive power and harmonic problems, which can easily interfere with the operation quality of power grid and bring risk to coal mining. In order to solve the above problems, the exact position and parameters of reactive power and harmonic influence must be defined based on the nonlinear dynamic modeling system, the simulation experiment must be carried out, and then the corresponding filtering device and reactive power compensation system must be provided to distinguish whether this kind of problem can be contained or not, so that the problem of this kind of substation can be solved effectively.
Keywords: nonlinear dynamics; PTSC filtering; reactive power compensation; system design
无功补偿系统在煤矿集团变电所中的有效利用,既能够根据变电线路运行状况,为发电机的运行提供适当保护,以便降低设备与系统内有功功率与电能的损耗,使变电设备系统的可使用寿命得以显著延长,同时凭借无功补偿系统,更能够有效遏制电网波动与谐波影响等问题,使系统电能质量得以改善,也有助于提高发电机的有功功率。因此,站在能源可持续发展与电网稳定运行的角度,设计人员理应对无功补偿与PTSC滤波装置给予充足的认识。
1 研究背景
本项目为某煤矿集团变电所无功补偿与谐波治理系统设计。现有变电所变一次侧额定电压为66kV,二次侧额定电压为6.3kV。在变电所工作期间,上午11时~下午1时通常选用大功率直流设备,而下午4:30~6:10时通常选用大功率变频设备,以便煤矿开采工作质量得以保障。根据调查资料可知,直流设备与变频设备受无功和谐波因素影响较严重,不但极易影响煤矿现场正常的供电质量,同时还会降低发电机的能耗利用率,极易使煤矿开采设备的应用受影响。……