基于比例谐振的网侧电流修正型APF控制

2019-08-05刘斌蔡淦王斌孟艳颍李伦全

电机与控制学报 2019年7期

刘斌 蔡淦 王斌 孟艳颍 李伦全

摘 要:针对LCL滤波器虽然电感量较小并对高频谐波电流具有更好衰减效果,但一直存在谐振的问题,提出在三相系统中引入网侧电感电流控制环,修正逆变侧电感电流给定的有源阻尼型控制方法,且从系统效率的角度,有源阻尼的方法优于加入无源阻尼。该方法除了能有效抑制LCL谐振,同时可改善入网电流的品质。不同于以跟踪工频给定为目标的光伏并网逆变器,有源电力滤波器(APF)更看重谐波电流的控制,对控制器的设计提出了更高的要求。通过在网侧电流修正环中引入谐振控制,提升系统的补偿性能。最后通过仿真和实验,证明了该控制方法的有效性。

关键词:LCL滤波器;有源电力滤波器;网侧电感电流;有源阻尼;谐振控制器

中图分类号:TM 464

文献标志码:A

文章编号:1007-449X(2019)07-0106-07

Abstract:Although LCL can be designed with smaller inductance value and can better damp higherorder harmonics, LCL may also cause resonance. For three phase system, an active damping method was proposed by introducing a gridside inductor current control loop to correct the inverter side inductor current reference. This controller is superior to the passive damping one from the point of system efficiency. By this resonance damping controller the performance of the current that is injected into the grid is also improved. Different from the photovoltaic inverter which is to track sinusoidal reference with mains frequency, the active power filter (APF) is to track distorted reference with many harmonics and this requires more challenging controller design. By introducing resonant controller in the correction loop, APF system performance is promoted, and the effectiveness of the controller is verified through simulations and experiments.

Keywords:LCL filter; active power filter; grid side inductor current; active damping; resonant controller

0 引 言

配電网中整流型非线性负荷的不断投入,对电网的供电质量带来很大影响,有源电力滤波器(active power filter,APF)可以实时地检测并补偿负荷谐波以及不平衡电流,该技术因此得到广泛地关注和研究[1-3]。由于APF要求输出电流跟踪富含各次谐波的给定,控制策略直接影响系统补偿效果。相较于单L滤波器,LCL滤波器具有对高频谐波电流更好的衰减效果且可减小电感量,在大功率应用场合,成本优势明显,显著缩减了装置体积。然而,LCL型滤波器极易出现谐振现象,需要额外采取阻尼方式才能保证系统稳定[4]。典型的解决办法是增加系统阻尼,相关的办法包括无源阻尼和有源阻尼2种。……

登录APP查看全文