APP下载

核电厂蒸汽转换系统安全阀动作原因分析

2019-05-29刘镇国蔡二灵

关键词:核电厂

刘镇国 蔡二灵

【摘 要】某核电厂在进行蒸汽转换系统切换时由于操作经验不足和设备故障导致一次侧安全阀动作,针对这一事件,论文从人员、设备和工作程序三个角度展开原因分析,并提出改进措施,为解决同类问题提供参考。

【Abstract】In a nuclear power plant, the action of primary side safety valve is caused due to the insufficient operation experience and equipment failure when the steam conversion system is switched. In view of this incident, the paper analyzes the causes from the perspective of personnel, equipment and work procedures, and puts forward improvement measures, so as to provide reference for solving similar problems.

【關键词】核电厂;蒸汽转换器;安全阀

【Keywords】nuclear power plant; steam transformer system; safety value

【中图分类号】TM63 【文献标志码】A 【文章编号】1673-1069(2019)03-0182-02

1 引言

核电厂蒸汽转换系统(STR)用于产生低压辅助蒸汽,通过辅助蒸汽分配系统(SVA)分配给核岛和常规岛各用户。蒸汽转换器系统主要由蒸汽转换器(001TX)、疏水箱(001BA)、疏水冷却器(001RP)、辅助蒸汽除氧器(001DZ)、排污箱(001CW)、给水泵(001PO、002PO)及相应的阀门和管道组成。来自主蒸汽系统(VVP)高压饱和蒸汽经两支并联的降压调节阀002/005VV降压到2 MPa.a后,进入蒸汽转换器001TX进口联箱,在转换器壳体内由一束高压传热管将蒸汽热能传至周围的给水,从而产生1MPa.a的辅助蒸汽。当电站两台机组正常运行时,辅助蒸汽由其中一台机组的STR产生,根据生产需要可进行两台机组STR的切换。

某核电站在执行2STR切换至1STR带载过程中,工作人员在SVA有较大负荷的情况下切换,调节系统未能正常响应,导致1STR一次侧安全阀1STR007VV动作,反应堆短时功率上升。本文针对该问题展开原因分析。(图1)

2 事件过程描述

工作人员按指令执行2STR切换至1STR带载,考虑到热功率的变化,主控先将电功率降低1MW。系统初态情况为:2STR蒸汽转换器一次侧压力6.8bar,二次侧6.6bar;2STR001MP定值A bar,2STR002MP对应定值6bar;1STR001/002MP定值均为0bar;SVA的核岛蒸汽用户9TEP系统有持续用汽。

现场工作人员按规程进行1STR启动前在线……