双膜法预脱盐水处理系统设计
2019-01-30刘艳丽
刘艳丽

【摘 要】某化学品公司现有除盐水系统需要将水源改为园区工业废水处理厂出水,且生产工艺有循环冷却水的使用需求,为此本技术方案推荐采用“超滤+反渗透”双膜法预脱盐工艺,双膜法的引入,使水处理工艺更加完善、灵活,可以满足不同水质、水量条件等复杂条件下的用水需求。
【Abstract】The existing desalination system of a chemical company needs to change the water source to the effluent of the industrial wastewater treatment plant in the park, and the production process has the use demand of circulating cooling water. Therefore, this technical scheme recommends the use of "ultrafiltration + reverse osmosis" double-membrane desalination process. The introduction of double-membrane process makes the water treatment process more perfect and flexible. It can meet the water demand under complex conditions such as different water quality and quantity conditions.
【关键词】反渗透;超滤;预脱盐;方案设计;废水回用
【Keywords】 reverse osmosis; ultrafiltration; desalination; scheme design; wastewater reuse
【中图分类号】TQ085+.4 【文献标志码】A 【文章编号】1673-1069(2019)10-0189-02
1 项目概况
某化学品公司生产工艺需使用脱盐水,现有的脱盐水处理工艺如下:
阳离子交换器→阴离子交换器→混合离子交换器→脱盐水。
现拟采用园区工业水处理厂处理后的出水,在现有离子交换前增加预脱盐工艺为基础,本方案建议采用“超滤+反渗透”双膜法预脱盐工艺,工艺流程如下:
带压工业自来水→自清洗过滤器→超滤装置→超滤产水池→增压泵→保安过滤器→高压泵→反渗透装置→除盐水池→外供水泵→用水点或后续处理工艺。
设计反渗透出力350m3/h,其中250m3/h可以直接去作为工业冷却水,100m3/h去现有离子交换系统进一步处理,以满足工艺用水以及锅炉补给水的使用要求。
2 方案设计基础
2.1 水质、水量
原水电导率<1100μs/cm,总硬度<250mg/L,总碱度<110 mg/L,游离余氯<0.5mg/L,进水浊度<1NTU;
系统最终规模为:350m3/h。
2.2 设计产水水质
产水电导率:≤20μS/cm。
2.3 回收率