APP下载

多因素对地下污水厂H2S与NH3浓度的影响

2018-09-30杨鹏刘雪峰门玉葵刘承东

土木建筑与环境工程 2018年5期
关键词:因素影响

杨鹏 刘雪峰 门玉葵 刘承东

摘 要:

依托現场实验测试,采用二阶正交数值仿真实验,以脱水机房为例,分析了温度、湿度及排风量对地下污水厂H2S和NH3浓度的影响,并提出了一种结合污染水平和排风能耗的综合评价指标。分析结果表明,脱水机房H2S和NH3浓度受温度和排风量交互效应影响显著(p<0.05)。在20 ℃时脱水机房内H2S和NH3浓度最低,比35 ℃时污染水平降低2.5倍,综合评价指标计算结果显示,在2.7次换气次数下综合评价指标较小,K值为4.5。对于处理量为10万t/d的污水厂,换气次数低于2.7次脱水机房的恶臭浓度偏高,高于2.7次排风能耗过大,取2.7次换气次数范围最为合理。

关键词:

地下污水厂;正交试验;仿真模拟;恶臭气体

中图分类号:X512

文献标志码:A 文章编号:16744764(2018)05012409

收稿日期:20171125

基金项目:

国家自然科学基金(51778234);广东省自然科学基金(2015A030310303);广东省省级科技计划(2017A020216024);中央高校基本科研业务费专项资金(B6150170)

作者简介:

作者简介:杨鹏 (1990),男,主要从事空气品质与环境控制研究,Email:yangpeng_hn@live.com。

刘雪峰 (通信作者),男,博士,副教授,Email:lyxfliu@scut.edu.cn。

Received:20171125

Foundation item:

National Natural Science Foundation of China (No.51778234);Natural Science Foundation of Guangdong

Province (No. 2015A030310303);Science and Technology Planning Project of Guangdong Province (No.2017A020216024);Fundamental Research Funds for the Central Universities (No. B6150170)

Author brief:

Yang Peng (1990),main research interests:air quality and environmental quality improvement, Email: yangpeng_hn@live.com.

Liu Xuefeng(corresponding author), associate professor,PhD,Email:lyxfliu@scut.edu.cn.

Effect of multi factor on H2S and NH3 concentration in

underground wastewater treatment plants

Yang Peng1,Liu Xuefeng1,Men Yukui1,Liu Chengdong2

(1.School of Electric Power, South China University of Technology,Guangzhou 510641,P.R.China;

2.Guangzhou Municipal Engineering Design and Research Institute, Guangzhou 510060,P.R. China)

Abstract:

With experiment test, a secondorder orthogonal experiment was carried out to analyze the weight of factors affecting H2S and NH3 concentration in sludge dewatering of underground wastewater treatment plants: temperature, humidity and exhaust volume, and according to pollution level and energy consumption, a comprehensive evaluation index was put forward. The results indicate that Interaction between temperature and exhaust volume is important to H2S and NH3 concentration (p<0.05). When the outdoor temperature is 20 ℃, the H2S and NH3 concentration of the dewatering machine room is the lowest. It is reduced by 2.5 times compared with 35 ℃. According to the comprehensive evaluation index, the minimum K value is 4.5 in the ventilation frequency of 2.7. Below 2.7 times of ventilation, the odor concentration is too high , and the energy consumption is too large when higher than the 2.7 times of ventilation. Therefore, the most appropriate number of ventilation is 2.7 for dewatering room with treatment capacity ten thousand per day.

Keywords:

underground wastewater treatment plants;orthogonal experiment;computer simulation;odors

温度、相对湿度、排风量是脱水机房恶臭逸散的主要影响因素,温度过高、排风量不足都会造成脱水机房内恶臭气体不断聚集,恶臭气体主要成分为H2S、NH3,臭阈值低、毒性大[13]。若不妥善治理,将会严重影响工作人员的身体健康,危害较大[45]。为保证地下工作环境的安全,设计的排风量普遍过大,污水厂通风系统的投入和运行费非常高,造成能源浪费[6]。

污水处理厂的除臭系统属于末端治理:对于已产生的恶臭气体先进行密闭、收集,再通过化学、生物等方法对其进行治理。……

登录APP查看全文

猜你喜欢

因素影响
腹部胀气的饮食因素
四大因素致牛肉价小幅回落
食品安全的影响因素与保障措施探讨
群众路线是百年大党成功之内核性制度因素的外在表达
哪些顾虑影响担当?
没错,痛经有时也会影响怀孕
扩链剂联用对PETG扩链反应与流变性能的影响
短道速滑运动员非智力因素的培养
基于Simulink的跟踪干扰对跳频通信的影响
《流星花园》的流行性因素