风力发电机故障统计与分析
2018-09-10陈超
陈超

摘 要:本文以大唐宝丰红石山风场的许继WT2000双馈异步风力发电机组为研究对象,针对风机常见的变桨故障、冷却故障、通讯故障、变频故障、齿轮箱故障和偏航故障6种常见故障类型进行统计分析,阐述故障的处理方法,然后对风机频发的故障进行解析,为今后风机的故障监测提供重心和依据。
关键词:风力发电;故障;原因;預防
中图分类号:TM315;TM307.1 文献标识码:A 文章编号:1003-5168(2018)07-0059-02
Fault Statistics and Analysis of Wind Turbine Generator
CHEN Chao
(Datang Henan Clean Energy Co., Ltd.,Zhengzhou Henan 450018)
Abstract: In this paper, the XJ WT2000 in Datang Baofeng Hongshishan wind DFIG as the research object, according to the common fan blade failure, cooling failure, communication failure, fault frequency, gearbox fault and yaw fault 6 common fault types were analyzed, elaborated the fault handling method, then the fault of the wind for frequent analysis, provided the basis for future fault monitoring center of gravity and wind turbine.
Keywords: wind power generation;failure;cause;prevention
随着对不可再生资源及环境保护的重视,风力发电渐渐成为城区供电的主力军。为了充分利用风能,不同型号不同能效的风力机组逐渐成型,风力发电技术也日渐趋于成熟。但是,受市场高速发展以及不同区域风能地形差异的影响,风力发电机组的可利用率并不是十分理想,监控系统有待优化。本文对特定风场特定机型的采集数据进行统计分析,从而找出风机较常见的几个故障,并提出对应的解决方法,为今后风机的故障监测提供依据。
1 风场环境及发电机组介绍
大唐宝丰红石山风电场主要分布于宝丰一带的山脊,海拔高度约420~700m,地势北高南低,具备运输和安装兆瓦级以上风电机组设备的能力。风电场70~80m高度年平均风速为6.3m/s,年平均风功率密度为266W/m2,风功率密度等级为2级。共安装23台2MW许继风力发电机组,风力发电机组出口电压为690V,每台风机配套一台35/0.69kV箱式变压器。许继WT2000双馈异步风力发电机组采用三叶片、齿轮箱、双馈异步发电机、并网额定功率为2 000kW的总体设计方案,WT2000/116机组的风轮直径为116m。……