摘要:火电厂烟道属于大截面烟道,由于锅炉结构的限制,烟道流场分布不均匀。尤其是脱硝出口烟道,普遍存在着催化还原反应不均匀、烟道直管段短的问题,烟气浓度场分布不均匀。在流场不均的烟道,单点取样测量的烟气数据不能代表烟气的实际参数,不能作为生产运行调节的参考依据。本文通过对比几种应用于烟气取样的典型取样技术,提出了适用于不均匀流场烟道的矩阵取样技术,为火电厂烟气取样分析提供指导。

关键词:大截面烟道;流场不均;矩阵取样

中图分类号:X701.2 文献标识码:A 文章编号:2095-672X(2018)03-0244-02

DOI:10.16647/j.cnki.cn15-1369/X.2018.03.147

Abstract: Flue section of thermal power plant is large cross section . Due to the limitation of boiler structure.Non-uniform of the flow field distribution is ubiquity .Especially the export smoke cross of denitrification. The problem of catalytic reaction is not uniform and straight pipe section of flue is short is ubiquity.Consistency gas is maldistribution .Uneven distribution of flue in the flow field ,the gas data of single point sampling measurement doesnt represent the actual data.It can not be used as a reference for production operation adjustment. In this paper , by comparing several kinds of typical probe technologies which are applied to gas probe. Optimized configuration solution of gas probe technologies ,is put forward to suit for gas probe technologies, and a reference is provided in the selection of gas probe system for the gas probe of thermal power plants.

Key words: Large section flue; Uneven flow field; Atrix sampling

燃煤机组烟气脱硝改造,由于场地空间限制,脱硝出口烟道较短,而且存在多处变径和拐角;火电厂烟道属于大截面烟道,烟道尺寸在幾米到十几米,流场不均普遍存在。由于烟道流场分布不均,脱硝出口NOX和NH3的浓度分布也不均匀。在运行过程中,脱硝出口NOX和NH3浓度的测量数据存在基本不变化或者波动较大的情况,不响应系统工况变化,还存在脱硝出口与脱硫出口所测NOX浓度偏差较大的情况。这些测量数据不但不能为生产运行提供指导,反倒给运行人员带来困扰,给脱硝系统投自动也带来较大障碍[1]。

这些问题都是在流场分布不均的烟道上,采用传统的单点取样方式所带来的。在不均匀流场,一个点的测量数据不能代表整个烟道的烟气浓度参数,该点的测量数据也失去了使用价值和意义。当前,NOX和NH3的浓度检测已经有较为先进的化学发光技术,测量精度可达到PPB级,导致NOX和NH3测量不准的主要原因集中在取样方式上。……