敦煌莫高窟微环境控制方式的CFD仿真与实验
2018-01-20张春庭苏伯民张正模
张春庭++苏伯民++张正模
内容摘要:为了确保对洞窟的控制方式和控制量不会对壁画和塑像有任何程度的损害,采用计算流体力学CFD技术对洞窟微环境引入的控制手段进行分析,结果表明主动抽风产生的气压以及壁画表面的风速都比主动送风方式要小。在对第131窟所做的空气交换率实验证实了CFD的分析结果。因此主动抽风控制方式在中小洞窟对于减小空气湿度以及降低二氧化碳浓度都具有良好的作用,同时对洞窟内的文物影响很小。
关键词:计算流体力学;主动抽风;主动送风
中图分类号:K854.3 文献标识码:A 文章编号:1000-4106(2017)06-0167-05
The CFD Simulation and Test of the Control Mode of the Mogao Grottoes Micro Environment
ZHANG Chunting1 SU Bomin2 ZHANG Zhengmo2
(1. Instrumention Technology and Economy Institute, Beijing 100055;
2. Dunhuang Acadmy,Gansu, Dunhuang 736200)
Abstract: In order to ensure that the control method and control variable of the caves will not damage the murals and statues to any degree, CFD technology was used to analyze the control means of the caves micro environment. The analysis results show that active ventilation creates lower pressure and mural surface wind speed than active air supply. The air exchange experiment in cave 131 confirms the results of CFD analysis. It can thus be concluded that using the active ventilation control method in smaller caves is effective in reducing air humidity and decreasing the concentration of carbon dioxide, lessening the influence on the cultural relics in the caves.
Keywords: CFD; active ventilation; active air supply
引 言
世界著名遗产地敦煌莫高窟地处戈壁腹地,是我国第一批列入世界遗产名录的文化遗产。敦煌莫高窟文化瑰宝的保护一直得到我国政府的高度重视。阴雨天气和沙尘天气导致洞窟微环境突变,对洞窟壁画的保存带来很大的负面影响[1][2]。阴雨天,外界环境空氣是高湿度,随着洞窟内外空气交换,窟内湿度升高,导致壁画损坏[3][4];在沙尘天气,沙尘进入洞窟,沉降于壁画或塑像表面,不仅从视觉上影响壁画的美观,而且对壁画造成潜在的危险。此外随着旅游业的不断发展,大量的游客参观使洞窟微环境改变,已经威胁到壁画的保存。游客参观带来的洞窟环境改变主要集中在温度、湿度、CO2、微生物和气溶胶等。CO2可造成壁画处于一个酸性环境中,对壁画保护造成潜在的威胁[5][6]。
莫高窟洞窟保护的最终目标是,开发一套微环境控制系统以更好的调节洞窟内的微环境,包括温度、湿度以及二氧化碳含量,从而更好地保护洞窟内的壁画、塑像等。……