ICP-AES分析高含量铷矿石中的氧化铷
2017-10-11陶丽萍
刘 氘,陶丽萍,石 华
(青海省地质矿产测试应用中心,青海 西宁 810008)
ICP-AES分析高含量铷矿石中的氧化铷
刘 氘,陶丽萍,石 华
(青海省地质矿产测试应用中心,青海 西宁 810008)
高含量铷矿石采用氢氟酸、高氯酸、硝酸、盐酸混合酸在200℃控制电热板上溶解,待到样品剩下1mL时用10mL 1+1王水提取后用称量法定容到100mL的容量瓶中,定量加入镉作为内标元素,用电感耦合等离子体光谱测试,通过测量该元素强度变化以及内标元素强度变化比较得到含量结果。通过加标回收试验得到回收率为97.5%~102%,在国家标准样品测试误差规定范围内,方法的有效测试范围为0.010%~50.00%。
高含量铷矿石;ICP-AES;镉内标
Abstract: High rubidium content ore using hydrofluoric acid and perchloric acid, nitric acid, hydrochloric acid at 200 DEG C temperature control heating board until the samples dissolved, 1mL left with 10mL 1+1 after extraction with aqua regia weighing legal volume to a 100mL volumetric flask, add quantitative cadmium as internal standard element, tested by inductively coupled plasma spectroscopy, by measuring changes the elements of strength and internal standard element strength changes compare the content.Methods the recovery rate was between 97.5%~102% and, and the standard test error was within the specified range. The effective range of the method was 0.010%~50%.
Key words: High content rubidium ore; ICP-AES; internal standard of Cd
铷的分析测试方法有很多种,传统经典的原子吸收分光光度法、原子发射分光光度法、溴化锂熔融X荧光法、等离子质谱法、电子探针分析等[1]。原子吸收分光光度法、原子发射分光光度法具有准确度高的特点,适用范围从0.02%至1.30%,对于更高含量的样品则不适用[2];等离子质谱法适用于低含量样品分析;溴化锂熔融X荧光法测试精密度很高,但是准确度不是很高。ICP-AES具有精密度高,准确度可靠、线性范围很广的特点[3]。本方法基于ICP-AES测试铷元素精密度高,准确度可靠的特点[4],研究了一套合适的样品前处理方法,同时采用称重法来定容,匹配内标测试,进一步提高了方法的准确度和可靠性,测试范围能够满足铷矿石边界品位的测试需求和高含量铷矿石测试需求[5]。
1 试验部分
1.1 仪器和主要工作条件
1.1.1 iCAP-6300等离子发射光谱仪:美国Thermo-fisher。……