APP下载

600 MW亚临界空冷机组电动给水泵改造方案探讨

2017-10-09沈峰,郝飞,谭锐

发电设备 2017年5期
关键词:汽轮机变频器效率

沈 峰, 郝 飞, 谭 锐

(国电科学技术研究院, 南京 210031)

600 MW亚临界空冷机组电动给水泵改造方案探讨

沈 峰, 郝 飞, 谭 锐

(国电科学技术研究院, 南京 210031)

为了提高600 MW亚临界空冷机组电动给水泵经济性,结合电动给水泵改汽动给水泵、液力耦合器改调速变频器这两种主要的给水泵改造技术路线,分别计算在不同改造方案下,机组对应不同负荷的改造效果。同时结合场地条件、负荷率、运行方式、投资等因素,针对不同的机组选择合适的改造方案。

亚临界空冷机组; 给水泵汽轮机; 液力耦合器; 变频器; 供电煤耗

Abstract: To improve the economy of a 600 MW subcritical air-cooling unit driven by electric feed pumps, there are in total two main technical strategies. One way is to use steam feed pump instead of electric feed pump, the other is to adopt frequency conversion instead of fluid coupling. Retrofit effects of the unit at different loads were calculated respectively for both the strategies. Considering the area conditions, load rate, operation mode and investment factors, appropriate retrofit schemes were proposed for the electric feed pump in different units.

Keywords: subcritical air-cooling unit; steam turbine for feed-water pump; fluid coupling; frequency converter; coal consumption of power supply

大容量空冷机组由于其背压高、且参数变化较大,按照GB 50660—2011 《大中型火力发电厂设计规范》规定,300 MW及以上直接空冷机组的给水泵配置为调速电动给水泵。在操作响应上,电动给水泵有着明显的优势。

汽动给水泵由于其较高的能量转化效率使之成为空冷机组的新选择。在运行操作及安全性上,汽动给水泵已完全可以满足大容量直接空冷机组的需求,且无论是单台100%容量,或者2台50%容量的布置方式均可以实现。

近些年来,机组负荷率呈逐年下降趋势,随着负荷的降低,液力耦合器调速损耗增大,转换效率降低,其经济性较差的缺点也越来越明显。而调速变频器在中低负荷下仍具有较高的转换效率,大大降低电动给水泵的耗电量。给水泵液力耦合器改调速变频器也成为节能降耗改造的一个方向。

1 600 MW直接空冷机组给水泵改造方案

1.1 机组概况

某600 MW亚临界直接空冷凝汽式汽轮机型号为NZK-600-16.7/538/538,机组配置3台50%容量电动给水泵。……