集中布置的多联空调机房噪声传播规律与消声量研究
2017-10-09许国强
郭 初,许国强
( 广东省建科建筑设计院有限公司,广州510500 )
集中布置的多联空调机房噪声传播规律与消声量研究
郭 初,许国强
( 广东省建科建筑设计院有限公司,广州510500 )
本文根据噪声的传播原理得出了集中布置的多联室外机房噪声的衰减与叠加规律,研究了拟建建筑物空调机房不同层数、与住宅不同距离的情况下空调机房噪声的传播规律,得出了机房对面住宅在达到《声环境质量标准》下,不同距离与不同层数的空调机房所需的消声量,从而计算出所需消声器的尺寸,对空调机房的设计与净空尺寸提供设计参考。
多联空调室外机房;噪声传播规律;消声量
Abstract:This paper analyses the attenuation and superposition rule of noise in centralized VRV unit outdoor room according to the principle of noise propagation, studied the noise propagation rule of the air conditioning room under different layers of the air conditioning room and different distance from the residence. Obtained the required noise elimination quantity of the conditioning room with different distance and different layers of air conditioning room under the“sound environment quality standards”. To calculate the required size of the muffler, and to provide reference for design of the size of air conditioning room.
Keywords:VRV unit outdoor room;Noise propagation rule;Noise reduction
如今,噪声污染越来越成为环境污染的一大因素,使用多联空调系统的建筑,由于多联空调室外机的运转设备是压缩机和风机,机组是通过与室外空气对流传热,单模块风机的风量通常达到了13500m3/h以上[1],机组的进风口及排风口不能封闭,机组运行一段时间后噪声增大,尤其是分层集中布置的空调机房,有可能对周边住宅造成噪声污染。所以对空调系统进行噪声控制以及空调机房在设计时考虑消声降噪措施尤为重要。而城市建筑的密度和间距不同,空调机房的噪声对周边建筑的影响程度也不同。所以在多联空调室外机机房设计时必须根据拟建建筑物所处的相对位置与距离进行消声设计,且不影响多联机组能效条件下,有必要采取有效可行的消声降噪措施,确保空调机房的噪声对周边建筑的影响达到声环境质量标准。……