浅谈碱度及钙硬度对循环水系统腐蚀的影响
2017-08-22武江波任虎刘强杨德志
武江波+任虎+刘强+杨德志


摘 要:公用循环水站将处理后的母液水作为补充水时,循环水系统腐蚀相对比较严重。以循环水站正常加氯气或者其他杀菌剂为前提,通过对比分析不同含量总碱度和钙硬度对循环系统腐蚀的影响。以赖兹钠指数为理论依据,得出循环水钙硬度和碱度均值都在125 mg/L时,系统呈腐蚀严重趋势,钙硬度和碱度都超过300 mg/L时,系统处于相对比较稳定的状态。
关键词:总碱度 钙硬度 腐蚀
中图分类号:X703 文献标识码:A 文章编号:1672-3791(2017)07(b)-0105-02
Abstract: When the treated water is treated as supplementary water, the corrosion of circulating water system is relatively serious. On the basis of the normal addition of chlorine or other fungicides, the effects of different concentrations of alkalinity and calcium hardness on the corrosion of the circulating system were analyzed. With Rytz sodium index as the theory basis, the circulating water calcium hardness and basicity in the mean 125 mg/L, a serious corrosion tendency, calcium hardness and basicity of more than 300 mg/L when the system is in a relatively stable state.
Key Words: Total alkalinity; Calcium hardness; Corrosion
北元化工集团在生产聚氯乙烯树脂的过程中产生大量的离心母液水。为了减少环保压力,为了提高经济效益,公司将其收处理后回用到循环水站。在实际运行过程中发现循环水系统腐蚀严重。在确定基本操作及指标控制的前提下,通过对比循环水不同含量的总碱度和钙硬度对循环水系统腐蚀的影响。
表1钙硬和碱度在控制在指标范围内,但数值比较低,铁离子超标严重。循环水中铁离子的来源有以下几个方面:(1)来自补水;(2)循环水系统腐蚀;(3)其他含铁离子物质泄漏进入循环水。通过聚合工段排查确认无泄漏,所以第3项“其他含铁离子物质泄漏”可以排除。以各项指标的平均值计算,循环水浓缩倍数按3计算,由表1可以算出因补水造成循环水含铁量为0.577 5 mg/L,因腐蚀造成循环水含铁量为1.302 5 mg/L。由表2可以算出因补水造成循环水含铁量为 0.498 75 mg/L,因腐蚀造成循环水含铁量为 0.106 mg/L。与表1相比,表2中钙硬度高了156.7%,总碱度高了227.77%,因腐蚀铁离子下降86.83%。……