【Abstract】The application of static pressure pile foundation in the construction of urban densely populated areas is becoming more and more extensive. This method has many problems in construction technology, complicated process and influence of construction quality. There are often quality problems in construction. The analysis and treatment of the quality of the pile foundation in the construction will affect the structural safety and service life of the building. In this paper, the quality of pile construction in a project to analyze the quality of the problem, find out the reasons and put forward the treatment.

【Key words】Static pressure pile;Quality problem;Cause analysis;Treatment method

1. 前言

静压桩施工工序多,工艺要求高。由于不需要使用泥浆做冲洗液,施工现场干净,不会排放废浆污染地表水和地下水,施工时噪音较小,因此静压桩施工对环境基本不造成污染。随着国家对环境保护的要求越来越严格,在所有的地基基础施工方法中,此法最适合于在城市人口密集的城市区域工程中采用。

2. 工程簡介

某会议中心及综合配套设施改造工程位于城中心繁华地带,四周为住宅和行政办楼,是一个集会议、宾馆、娱乐为一体的综合性公共建筑群。该工程占地面积123467平米,总建筑面积68091平米,其中地下一层,地上四层,由三个单体建筑通过两个大堂连成一体,建筑风格宏伟庄严。基础由中500mm预制混凝土离心管桩(PHC)和桩顶承台共同组成,设计桩数4308根,桩长13~33米不等,混凝土标号c80,采用的静压桩机型号400T和600T。以下结合本工程就桩基施工中经常遇到的质量问题、原因分析及解决方法进行探讨。

3. 施工中遇到的质量问题

(1)桩位偏差过大。

(2)桩身倾斜过大。

(3)桩身断裂。……