APP下载

超声造影检查在睾丸扭转中的诊断价值

2016-11-09李秋枫朱一锋何淑波

中国性科学 2016年8期

李秋枫 朱一锋 何淑波

【摘要】目的:观察分析超声造影检查在睾丸扭转中的诊断价值。方法:选取2013年1月至2015年9月我院收治的经手术和临床随访证实的睾丸扭转患者共计66例,按照随机数表法分为观察组(n=33)和对照组(n=33),对照组应用常规超声检查,观察组应用超声造影检查。观察比较两组患者诊出睾丸扭转的符合率、不同类型睾丸扭转检出率以及两种检查方法的超声表现情况。结果:观察组患者诊出睾丸扭转符合率(84.85%)明显高于对照组患者诊出睾丸扭转符合率(42.42%),差异具有统计学意义(P<0.05)。同时,观察组睾丸完全扭转检出率(51.52%)和睾丸不完全扭转检查率(33.33%)均高于对照组患者(12.12%、30.3%),数据差异具有统计学意义(P<0.05)。结论:超声造影检查诊断患者睾丸扭转符合率高,同时能够准确判定睾丸缺血受损的程度和范围,为睾丸扭转诊断以及评估提供重要影像学资料。

【关键词】超声造影检查;睾丸扭转;常规超声检查;诊断价值

The diagnostic value of contrast-enhanced ultrasound in testicular torsionLI Qiufeng1, ZHU Yifeng2, HE Shubo3. 1.Ultrasound Medicine Department, Wanning City Peoples Hospital, Wanning 571500, Hainan, China; 2.Urology Department, Wanning City Peoples Hospital, Wanning 571500, Hainan, China; 3.Oncology Department, Hainan Province Nong Kennada Hospital, Danzhou 571700, Hainan, China

【Abstract】Objectives: To study the diagnostic value of contrast-enhanced ultrasound in testicular torsion. Methods: 66 cases with testicular torsion from January 2013 to September 2015 in our hospital were researched, and according to the random number table were divided into observation group (n=33) and control group (n=33). Control group were treated by Color Doppler ultrasonography, while observation group used CEUS. The diagnosed testicular torsion compliance rate, different types of testicular torsion detection rate and the performance of the two methods of ultrasound was compared. Results: The diagnosed testicular torsion compliance rate of observation group (84.85%) was significantly higher than the control group (42.42%), with statistically significant difference (P<0.05). At the same time, the testicular torsion complete detection rate (51.52%) and incomplete testicular torsion checking rate (33.33%) in observation group were higher than the control group (12.12%, 30.3%), with statistically significant difference (P<0.05). Conclusions: CEUS is consistent with the diagnosis of patients with high testicular torsion rate. At the same time, it can accurately determine the testicles missing blood damage extent and scope, which provides important image data for diagnosis and assessment of testicular torsion.

【Key words】CEUS; Testicular torsion; Conventional ultrasonography; Diagnostic value

【中图分类号】R697+.24【文献标志码】A

睾丸扭转又称为精索扭转,其发病机制多因为睾丸和精索本身的活动度加大以及解剖异常而引发扭转,初期扭转以及轻度扭转可以导致静脉淤血肿胀以及回流出现障碍,严重的还能致使动脉供血出现障碍而引发睾丸缺血坏死。睾丸扭转属于泌尿科的严重急症之一,同时也极其容易出现漏诊和误诊,因此在早期准确、迅速的诊断出病症能够有效减少患者睾丸出现坏死的情况是抢救成功的关键[1,2]。临床研究表明,超声检查对于治疗前确定睾丸缺血受损的程度和范围效果显著,被认为是最为有效且安全的影像学检查方法之一。但是其不足之处是在诊治婴幼儿患者时其睾丸血流信号相对较弱,再加上婴幼儿患者在治疗时的不配合,很大程度上会影响诊治结果,导致漏诊和误诊发生,影响患者的生命健康[3]。……

登录APP查看全文