2016-09-26马玉良王伟民刘健赵红卢明瑜李琪

中国循环杂志 2016年8期
关键词:支架

马玉良,王伟民,刘健,赵红,卢明瑜,李琪

冠状动脉旋磨标签外使用的安全性

马玉良,王伟民,刘健,赵红,卢明瑜,李琪

目的:探讨冠状动脉旋磨治疗在适应证标签外使用的安全性。

方法:顺序入选2010-01至2015-12北京大学人民医院行旋磨治疗的112例患者,列出9项旋磨需注意的非标签适应证包括:静脉桥血管,大量血栓病变,无保护左主干病变,急性心肌梗死罪犯病变,大夹层病变,严重左心室功能不全(左心室射血分数<30 %),严重三支病变,长病变(≥25 mm),成角病变(≥45°)。具有上述≥1项非标签使用的患者,列入旋磨标签外组(67例,59.8 %);无上述相对禁忌使用旋磨术的患者,列入标签内组(45例,40.2 %)。比较两组患者旋磨相关并发症(慢血流/无复流、旋磨头坎墩、冠状动脉穿孔、导丝断裂)和住院期间不良事件(紧急外科搭桥、急性支架内血栓、心原性死亡)的发生率。

结果 :(1)慢血流/无复流是最常见的旋磨并发症,标签外组与标签内组相比差异无统计学意义(4.5 % vs 8.9 %,P>0.05)。1例患者发生旋磨头坎墩,发生于标签外组(1.5 % vs 0 %,P>0.05)。(2)1例患者发生急性支架内血栓,位于标签内组(2.2 % vs 0 %,P>0.05);1例患者发生心原性死亡,位于标签外组(1.5 % vs 0 %,P>0.05)。

结论:标签外使用旋磨并未增加慢血流/无复流发生率,其他严重并发症和住院期间不良事件罕见。

冠状动脉疾病;钙化病变;旋磨术

Abstract

Objective:To explore the application safety for off-label using of rotational atherectomy.

Methods:A total of 112 patients received rotational atherectomy in our hospital from 2010-01 to 2015-12 were enrolled in this study. There were 9 off-label indications for using of rotational atherectomy which included vein grafts,massive thrombotic burden,unprotected left main coronary artery disease,culprit lesions of acute myocardial infarction,severe coronary dissection,significant impaired left ventricular function (LVEF<30%),severe three-vessel coronary disease,diffuse long coronary lesions (≥25mm)and angulation lesions (≥45°). The patients were divided into 2 groups: Off-label group,the patients with ≥ 1 above mentioned indication(s),n=67 (59.8%) and On-label group,the patients without any indication,n=45 (40.2%). Rotational atherectomy related complication rates were compared between 2 groups including slow flow/no flow,stuck of rotablator,coronary artery perforation,guide wire fracture and in-hospital MACE as urgent CABG,acute in-stent thrombosis and cardiac death.

Results:①The most common complication was slow flow/no flow and its occurrence rates were similar between 2 groups (4.5% vs 8.9%),P>0.05. ②Off-label group had 1 patient with stuck of rotablator (1.5% vs 0%) and 1 cardiac death (1.5% vs 0%),both P>0.05; On-label group had 1 patient with acute in-stent thrombosis (2.2% vs 0%),P>0.05.

Conclusion:Off-label using of rotational atherectomy did not increase the incidence of slow flow/no flow in relevant patients,other severe complications and in-hospital MACE occurrence were also rare.

(Chinese Circulation Journal,2016,31:737.)

冠状动脉旋磨(rotationalatherectomy,RA)是处理严重钙化病变的重要手段[1]。当前药物洗脱支架(drug-eluting stents,DES)时代,旋磨的意义主要在于斑块修饰,为随后球囊扩张及支架置入提供有效保障,因此旋磨技术使得介入治疗拓展到更为复杂的领域[2-5]。……