Acoustic properties of HIFU ablation for uterine fibrods with different T2WI signal

2016-09-23,,,,,

中国介入影像与治疗学 2016年7期
关键词:差异信号疗效

, , , , ,

(State Key Laboratory of Ultrasound Engineering in Medicine Co-founded by Chongqing and the Ministry ofScience and Technology, Chongqing Key Laboratory of Ultrasound in Medicine and Engineering,College of Biomedical Engineering, Chongqing Medical University, Chongqing 400016, China)



·基础与实验研究·

Acoustic properties of HIFU ablation for uterine fibrods with different T2WI signal

LIFei,RANJianbo,HUANGHaoran,WANGZhengyi,XUJie,LIFaqi*

(StateKeyLaboratoryofUltrasoundEngineeringinMedicineCo-foundedbyChongqingandtheMinistryofScienceandTechnology,ChongqingKeyLaboratoryofUltrasoundinMedicineandEngineering,CollegeofBiomedicalEngineering,ChongqingMedicalUniversity,Chongqing400016,China)

ObjectiveTo explore the acoustic properties of HIFU ablation for uterine fibrods with different T2WI signal. MethodsTotally 45 fibroid specimens were collected. The uterine fibroids were subdivided into hypo-intense group, iso-intense group and hyper-intense group based on signal intensity on T2WI MR before surgery. The specimens were underwent the sound velocity and sound attenuation detection by using a pulse-echo technique. ResultsThe hypo-intense, iso-intense and hyper-intense uterine fibroids were 7, 9, 29, the sound velocity of the three types uterine fibroids were (1 597.86±15.17)m/s, (1 586.70±10.83)m/s, (1 576.57±10.06)m/s, there was a significantly statistics difference among hypo-intense and hyper-intense groups, and between iso-intense and hyper-intense groups (allP<0.05); the sound attenuation of three types uterine fibroids were (4.03±1.34)dB/cm, (2.54±1.17)dB/cm, (1.04±0.66)dB/cm, there was a statistically significantly difference between hypo-intense, iso-intense and hyper-intense groups (bothP<0.05), and between hypo-intense and iso-intense groups (P<0.05). ConclusionThe differences among uterine fibroids with different T2WI signal in sound velocity and sound attenuation may be one of the important factors of causing the efficacy difference when ablating uterine fibroids by HIFU.

Uterine fibroids; High-intensity focused ultrasound ablation; Magnetic resonance imaging; Sound velocity; Sound attenuation

子宫肌瘤因常伴月经量增多、经期延长、痛经、继发贫血、不孕等症状而需进行临床治疗。与手术治疗相比, HIFU因其安全、有效、无创、可保留子宫完整性等特点,在临床应用中展现出良好的前景。研究[1]表明,根据术前MR T2WI信号强度可对子宫肌瘤HIFU消融的疗效进行评价;在T2WI低、等、高信号子宫肌瘤中,对低、等信号肌瘤容易消融,而对高信号肌瘤消融较困难[2-5]。Bhatia等[6]对子宫肌瘤的声学性质进行分析,发现子宫肌瘤个体间组织声速和声衰减差异较大,但子宫肌瘤MR T2WI不同信号组织声学性质的研究鲜见;HIFU治疗时,声衰减和声速是影响将超声能量转化为热能的重要因素[7]。因此,本研针对声衰减和声速,通过对不同T2WI信号子宫肌瘤离体组织的声学性质测量,探讨导致HIFU不同T2WI信号子宫肌瘤疗效差异的原因。

1 材料与方法

1.1一般资料收集2014年12月—2015年6月在重庆医科大学附属第一医院妇科经外科手术切除的子宫肌瘤标本45个。所有患者术前均接受常规MR T2WI检查,并经2名有多年经验的专业医师按照Zhao等[4]的分类标准将肌瘤分为T2WI低信号(信号强度与骨骼肌大致相当)、等信号(信号强度高于骨骼肌,但低于子宫肌壁)、高信号(信号强度等于或大于子宫肌壁)3类。术后立即将标本放入4℃生理盐水并送检。

1.2组织声学性质测量采用脉冲插入取代法测量组织的声学性质[8],主要仪器包括:数字示波器(Tektronix科技有限公司),信号发生器(OLYMPUS公司),BCU-74-6W水浸式探头线(OLYMPUS公司),2个1.0 MHz BCU-74-6W水浸式探头(OLYMPUS公司),1个作为发射换能器T1,1个作为接收换能器T2(图1)。……