王勋玺

【摘 要】新发布的《混凝土结构设计规范》(GB 50010-2002,以下简称混凝土规范)中,对钢筋混凝土结构伸缩缝最大间距的要求比原规范严格了,规范用词由"可"改为"宜"。这就要求在结构设计中,设计者必须认真对待由于超长给结构带来的不利影响,当增大结构伸缩缝间距或者是不设置伸缩缝时,必须采取切实可行的措施,防止结构开裂。

【关键词】后浇带;设计;施工

[文章编号]1619-2737(2016)05-19-301

【Abstract】The new release of "Design of Concrete Structures" (GB 50010-2002, hereinafter referred to as concrete specification), the largest reinforced concrete structure expansion joint spacing requirements than the original specifications strict, standardized wording from "may" to "should" . This requires structural design, the designer must be taken seriously due to the adverse effects of long to bring structure, when increasing the spacing structure expansion joints or expansion joints is not provided, you must take practical measures to prevent cracking of the structure.

【Key words】After pouring belt;Design;Construction

在适当增大伸缩缝最大间距的各项措施中,在结构施工阶段采取防裂措施是国内外通用的减小混凝土收缩不利影响的有效方法,我国常用的做法是设置施工后浇带。另外,当建筑物存在较大的高差,但是结构设计根据具体情况可不设置永久变形缝时,例如高层建筑主体和多层(或低层)裙房之间,也常常采用施工后浇带来解决施工阶段的差异沉降问题。这两种施工后浇带,前者可称之为收缩后浇带,后者可称之为沉降后浇带。本文就施工后浇带的设计与施工,结合工程实践,谈谈笔者的看法。

1. 后浇带的设计

1.1 当建筑结构的平面尺寸超过混凝土规范规定的伸缩缝最大间距(混凝土规范第9.1.1条)时,可考虑采用施工后浇带的方法来适当增大伸缩缝间距。但一般地上结构由于受环境温度变化影响较大,所以伸缩缝最大间距不宜超过混凝土规范限值过多,同时应注意加强屋面保温隔热,采用可靠的、高效的外墙外保温,并适当提高外纵墙、山墙、屋面等重要部位的纵向钢筋配筋率。……