EAST中性束注入器水流热量累积测量系统误差分析
2016-04-19胡纯栋许永建张为堂中国科学院等离子体物理研究所合肥230031
陈 宇 胡纯栋 许永建 于 玲 栗 翔 张为堂(中国科学院等离子体物理研究所 合肥 230031)
EAST中性束注入器水流热量累积测量系统误差分析
陈 宇胡纯栋许永建于 玲栗 翔张为堂
(中国科学院等离子体物理研究所合肥 230031)
摘要水流量热法是强流离子束束功率测量常用的方法,由于测量仪表安装位置的问题,EAST(Experimental Advanced Superconducting Tokamak)全超导托卡马克中性束注入水流热量累积测量系统中存在不可忽略的误差。本文结合水流热量累计测量系统的原理分析其误差的来源,针对其中由于采集时间有限和真空室内外热传递损失三部分误差来源进行了详细的分析和修正,将沉积功率百分比由73.72%提高到86.27%,修正结果显著。最终将修正方法嵌入到现有的沉积功率计算系统中,实时地进行误差修正,从而得到更精确的沉积在热承载部件上的功率沉积,为功率沉积分布和中性化效率的精确测量提供依据。
关键词中性束注入器,水流热量累积测量系统,误差修正
国家磁约束核聚变能发展研究专项(No.2013GB101001)和国家自然科学基金(No.11575240)资助
第一作者:陈宇,女,1991年出生,2013年毕业于华北电力大学,现为硕士研究生,核能科学与工程
Supported by the National Magnetic Confinement Fusion Science Program of China(No.2013GB101001)and National Natural Science Foundation of China(No.11575240)
First author:CHEN Yu,female,born in 1991,graduated from North China Electric Power University in 2013,master student,major in nuclear science and engineering
Error analysis of water flow calorimetry system of EAST neutral beam injector
CHEN YuHU ChundongXU YongjianYU LingLI XiangZHANG Weitang
(Institute of Plasma Physics,Chinese Academy of Sciences,Hefei 230031,China)
AbstractBackground:Water flow calorimetry is often used to measure the beam power of high intensity ion beam.There are some inevitable errors in water flow calorimetry system of Experimental Advanced Superconducting Tokamak(EAST)neutral beam injector,due to the position of the measuring instrument and acquisition time.Purpose:This study aims to correct these errors.Methods:This paper analyzes the factors inducing errors of the water flow calorimetry system,and then carries out quantitative calculation method for main error factors,and finally embeds the result into an existing data processing system.Results:Take the shot 58003 as an example,the deposition power is changed from 73.72%to 86.27%before and after correction.Conclusion:The accurate results lay a basis for the exact calculation of beam power deposition distribution and neutralization efficiency.
Key wordsNeutral beam injector,Water flow calorimetry,Error correction
中性束注入(Neutral Beam Injection,NBI)加热是全超导托卡马克实验装置最有效的加热手段之一,一直是受控核聚变领域的一个研究热点[1-4]。中性束注入器可以将高能带电粒子转化为中性粒子注入到等离子体中,用以加热等离子体、驱动等离子体电流。为配合先进实验超导托卡马克(Experimental Advanced Superconducting Tokamak,EAST)的物理实验研究,NBI研究室先后研制了两条中性束注入加热系统(4-8 MW,10-100 s),并成功实现了对EAST等离子体加热[5-11]。……