定子绕组匝间短路对发电机电磁转矩特性的影响
2016-04-07赵洪森戈宝军陶大军文茹馨
赵洪森 戈宝军 陶大军 文茹馨 邢 广
(1.哈尔滨理工大学电气与电子工程学院 哈尔滨 150080
2.黑龙江省电力科学院 哈尔滨 150030
3.哈尔滨电机厂有限责任公司 哈尔滨 150040)
定子绕组匝间短路对发电机电磁转矩特性的影响
赵洪森1戈宝军1陶大军1文茹馨2邢广3
(1.哈尔滨理工大学电气与电子工程学院哈尔滨150080
2.黑龙江省电力科学院哈尔滨150030
3.哈尔滨电机厂有限责任公司哈尔滨150040)
摘要基于场路耦合原理,首先建立了能够充分考虑发电机电磁饱和、磁极形状和齿槽效应的有限元数学模型,并采用麦克斯韦张量法计算了同步发电机定子内部短路故障前后的电磁转矩。通过对故障前后电磁转矩的频谱分析得出,定子发生内部短路故障后会产生很强的基频电磁转矩和二倍频电磁转矩。在此基础上,研究了暂态过程中基频电磁转矩、二倍频电磁转矩以及稳态过程中二倍频电磁转矩随故障匝数和短路位置的变化规律,该结果对于同步发电机内部短路故障的监测与诊断具有重要意义。
关键词:发电机短路故障电磁转矩场路耦合麦克斯韦张量法
Influence of Stator Winding Inter-Turn Short-Circuit Fault on Generator Electromagnetic Torque Characteristics
ZhaoHongsen1GeBaojun1TaoDajun1WenRuxin2XingGuang3
(1.College of Electrical and Electronic EngineeringHarbin University of Science and Technology Harbin150080China 2.Heilongjiang Electric Power Research InstituteHarbin150030China 3.Haerbin Electric Machinery Company LimitedHarbin150040China)
AbstractBased on the field-circuit coupled principle,the finite element mathematics model fully considering generator electromagnetic saturation,pole shape,and slot effect is built in this paper.The electromagnetic torque before and after the short-circuit fault in the synchronous generator stator winding is calculated by the Maxwell’s tensor method.The strong fundamental frequency and double fundamental frequency electromagnetic torques are found by analyzing the electromagnetic torque spectrum after the stator short-circuit fault.Furthermore,the change rules of the fundamental frequency and double frequency electromagnetic torques in the transient process and the double frequency electromagnetic torque in the steady state along with the short-circuit fault turns and position are revealed.The results are important for diagnosis and detection of the short-circuit faults within synchronous generator stators.
Keywords:Generator,short-circuit fault,electromagnetic torque,field-circuit coupled,Maxwell’s tensor method
0引言
同步发电机定子绕组匝间短路是一种常见的电气故障,随着发电机单机容量的不断增大和对发电机安全可靠性的要求不断提高,国内外学者愈加重视发电机定子绕组内部故障诊断和保护[1-4]。常规的监测与诊断系统中,主要以测量分析发电机电气参数变化情况为主[5-9]。近些年已有学者提出以发电机定子径向振动特征作为定子绕组匝间短路故障的监测量,为此类故障的研究开辟了新思路[10,11]。……