LLC全桥变结构控制高压直流变换器
2016-03-15卢绍成邓春明李步锦韦唯危秋珍
卢绍成 邓春明 李步锦 韦唯 危秋珍
摘 要: 当LLC全桥变换器的变压器副边绕组匝数较多时,分布电感和分布电容较大,在变换器的幅频特性中出现附加的谐振峰,使调频控制的控制范围减小,甚至完全失效。提出LLC全桥调频控制和移相控制相结合的变结构控制方法,兼顾扩大控制范围和减小开关应力两方面的性能。根据大功率配网故障定位仪的要求,研制了LLC全桥变结构控制的高压直流变换器样机。用F28335 DSP实现整机控制,完成调频和移相控制的转换,并根据故障状态,分别实现恒流、恒功率和恒压反馈控制。设计的高压直流变换器,最大输出电压为20 kV,最大输出电流为0.5 A,最大输出功率4 kW。样机在实际应用中取得良好效果,验证了分析方法和设计方案的正确性。
关键词: LLC全桥变换器; 高压直流变换器; 变结构控制; 故障定位
中图分类号: TN773?34; TM46 文献标识码: A 文章编号: 1004?373X(2016)04?0145?04
HVDC converter with LLC full bridge variable structure control
LIU Longhua1, HUANG Hongquan2, HUANG Qizhe1, LI Minqiang1, LU Shaocheng1,
DENG Chunming1, LI Bujin1, WEI Wei1, WEI Qiuzhen1
(1. Hechi Power Supply Bureau, Guangxi Power Grid Co., Ltd., Hechi 547000, China;
2. College of Electrical Engineering, Guangxi University, Nanning 530004, China)
Abstract: The large distributed inductance and distributed capacitance caused by the more number of transformer secondary windings makes the unexpected resonant peak appear in amplitude?frequency characteristic of the converter, which can reduce the control range of the frequency modulation control (FMC), or result in complete failure. A new variable structure control method in combination with LLC full bridge FMC and phase?shifting control (PSC) is proposed, which can expand the control range and reduce the switching stress. According to the requirements of the high?power distribution network fault locator, the prototype of HVDC converter with LLC full bridge variable structure control was developed. The complete machine control is realized by DSP F28335 to accomplish the conversion between FMC and PSC. The constant current, constant power and constant voltage feedback control are implemented according to the fault state. The maximum output voltage of the HVDC converter is 20 kV, maximum output current is 0.5 A, and maximum output power is 4 kW. The prototype achieved perfect effect in practical application. The correctness of the analysis method and design scheme was verified.
Keywords: LLC full bridge converter; HVDC converter; variable structure control; fault location
0 引 言
LLC桥式变换器具有变压器利用率高、功率开关管应力小、电流波形好等特点,在大功率开关变换器中应用广泛。移相控制的LLC变换器控制方式简单,输出调节范围宽,可实现部分功率开关管的软开关[1?6]。基于谐振特性的调频控制LLC变换器能实现全部功率开关管的软开关[7?9],但其最高工作频率受功率器件的限制,输出调节范围不大。在研制配网故障定位用的高压直流变换器时发现:当变换器的输出电压很高且负载电阻较大时,变压器输出绕组的分布电感和分布电容不能被忽略,LLC桥式变换器中出现附加的高频谐振峰,使调频控制方式完全失去输出控制能力,必须采用其他控制方式。……