APP下载

测震台站智能隔离防雷系统的设计与实现①

2016-01-18孙宏志,李秀丽,雷晨等

地震工程学报 2015年3期

测震台站智能隔离防雷系统的设计与实现①

E-mail:s6800@163.com。

孙宏志, 李秀丽, 雷晨, 卢山, 赵龙梅, 孙恺微, 高业欣

(辽宁省地震局,辽宁 沈阳 110034)

摘要:介绍一种测震台站智能隔离防雷系统的设计实现。其电源部分设计为步进电机控制双电瓶交换充电、放电,保证设备与交流市电完全隔离;信号传输部分设计为通过无线局域网(WLAN)将测震信号传输到网关,再通过有线网络进行数据传输。此设计的优点是使测震核心设备与市电和外线完全物理隔离以达到最好的防雷效果。同时制作先进的NEMS传感器用于检测空间电磁场的变化,根据相应算法判断当地是否发生雷电,在附近有雷电发生时可控制断开信号线、市电等达到保护相关仪器的目的。

关键词:测震台站; 隔离防雷; 纳米机电系统; 无线局域网

收稿日期:①2014-09-24

基金项目:辽宁省地震局科研专项(LZ-K201502)

作者简介:孙宏志(1973-),男(汉族),辽宁省沈阳人,硕士,高级工程师,从事地震仪器研制与电磁传感器研究工作。

中图分类号:P315.78; TU895文献标志码:A

DOI:10.3969/j.issn.1000-0844.2015.03.0878

Design and Implementation of an Intelligent Isolated Lightning

Protection System for Seismic Stations

SUN Hong-zhi, LI Xiu-li, LEI Chen, LU Shan, ZHAO Long-mei, SUN Kai-wei, GAO Ye-xin

(EarthquakeAdministrationofLiaoningProvince,Liaoning110034,Shenyang,China)

Abstract:To develop a system to protect the instruments of seismic stations from being damaged by lightning, we used a single-chip microcontroller as the core of the system to control the other chips and hardware. We used an industrial GPRS module to translate information from remote seismic stations to the seismic net monitoring center, and a WIFI module to transfer data between our system and a local wireless router. We used a magnetoelectric nano-electromechanical system (NEMS) sensor probe to detect the electromagnetic field (thunder). The connection status of the seismic signal line and the power line was controlled by the stepping motor of the single-chip microcontroller. In addition, we designed a system with a double internal 12 V DC switching power supply and a double inverter 220 V AC power supply for controlling the charging and discharging of the double storage batteries. When one storage battery is providing power to our system, the other is connected to the DC power for charging. This design ensures the complete isolation of our equipment from AC power. Furthermore, the system is able to transfer seismic data to the gateway using the wireless local area network, and simultaneously monitor changes in the electromagnetic space field with the NEMS sensor. The system can receive or control information from the monitoring center at any time, and can also control the connection status of the AC power and signal lines with the stepper motor. The double internal DC and AC power supply reduces the signal breakdown faults caused by power failure. This device can effectively protect seismic station instruments from damage by lightning, and improve the continuous operation ratio of seismic data.

Key words: seismic station; isolated lightning protection; nano-electromechanical system; wireless local area network

0引言

雷暴天气带来的强降水、大风、强光、强电场、强电流、强声波、电磁脉冲辐射、无线电噪声等,对人类社会产生巨大的危害。全球每年因雷击造成损失达数百亿美元。雷电灾害也是传统测震台站的主要灾害之一[1],由于雷电危害损坏观测技术系统,造成工作中断、监测资料缺损。我国年平均雷电日25天,高的可达100多天,大部分测震台站都受雷电干扰,严重的和比较严重的约占1/3至1/4[2]。因此做好防雷工作,保证观测技术系统正常运行,产出连续、稳定、可靠的数据,减少损失是有重要意义的[3]。……

登录APP查看全文