地铁引起的振动对框架结构的影响及隔振研究-以某教学楼为例
2016-01-18凌育洪,吴景壮,马宏伟
第一作者 凌育洪 男,博士,高级工程师,1969年生
通信作者 马宏伟 男,博士,副教授,1973年生
地铁引起的振动对框架结构的影响及隔振研究-以某教学楼为例
凌育洪1,2, 吴景壮1, 马宏伟3
(1.华南理工大学 建筑设计研究院,广州510640; 2.华南理工大学 亚热带建筑科学国家重点实验室,广州510640;3.华南理工大学 土木与交通学院,广州510640)
摘要:地铁振动对多高层框架结构有一定影响,以广州某教学楼为例进行了研究。首先测量了建筑场地的环境振动,发现场地z向振级大于水平振级,并超出限值要求;将场地最不利加速度时程作为一致激励进行了上部结构的振动响应分析,结果表明3.15-31.5 Hz频段的振动被放大,结构的z向振级逐层增大;对教学楼基底设置钢弹簧隔振装置后,分析结果表明该措施可有效降低23%的地铁振动,并满足限值要求。
关键词:地铁;环境振动;1/3倍频程;一致激励;基底隔振
基金项目:华南理工大学亚热带建筑科学国家重点实验室开放基金资助项目(2014KB28)
收稿日期:2014-06-30修改稿收到日期:2014-09-30
中图分类号:X827文献标志码: A
Effects of subway vibration on a frame structure and its vibration isolation
LINGYu-hong1,2,WUJing-zhuang1,MAHong-wei3(1. Architecture Design Research Institute, South China University of Technology, Guangzhou 510640, China; 2. State Key Laboratory of Subtropical Building Science, South China University of Technology, Guangzhou 510640, China; 3. School of Civil Engineering and Transportation, South China University of Technology, Guangzhou 510640, China)
Abstract:The vibration caused by subway has a certain effect on multilayer frame structures and high-rise frame structures. Aiming at the vibration isolation issues of a certain teaching building located in Guangzhou City, the environmental vibration of the building site was measured. It was shown that the vertical vibration level of the building site is beyond the limit of codes and higher than the horizontal vibration level; in the dynamic response analysis of the upper structure, the most unfavorable vibration acceleration time history of the building site is taken as a consistent excitation to the upper structure, its vibration response of 3.15Hz ~ 31.5Hz is amplified, the vertical vibration level of the structure increases layer by layer; the vertical vibration caused by subway reduces by 23% and meets the limit of codes after puting a steel spring floating vibration isolation device on the base of the building.
Key words: subway; environmental vibration; 1/3 octave; consistent excitation; base vibration isolation
地铁在成为城市交通工具的同时,其引起的振动问题也日益突出,使建筑物墙体开裂和结构疲劳损伤。地铁引起的振动特性与车辆特性、轨道类型、隧道结构、土层和结构状况、车速、车长和轨道平面的曲率半径等因素有关[1-3];地铁运行引起轨道振动的优势频率与扣件类型有关,其振动频率分布在1~1 000 Hz,峰值在500 Hz左右[4]。振动传至隧道周边土体后,表现为振幅随距离和地铁埋深的增加而减小[5-6],高频成分的衰减比低频成分快,振动优势频率一般在40~80 Hz,传至结构后则以低频为主,但也有学者得出城市地铁引起的振动优势频率在10 Hz以下[6]。……