摘要:针对国内现有结构设计及控制模式比较成熟的供热机组容量偏小,新建高参数机组存在供热能力不足的问题,提出对现有300 MW空冷机组进行高背压改造的方案,通过改造后运行参数和供热效果分析,认为改造方案可行,改造效果兼具安全性和经济性,是现阶段通过现有机组改造解决北方城市供热的合理方案。

关键词:空冷机组;高背压;供热

收稿日期:2014-09-16

作者简介:赵岩(1980—),男,会计师,主要从事电热力市场管理工作。

中图分类号:TM311

文献标志码:B

文章编号:1001-9898(2015)02-0047-02

Abstract:Aiming at the problem of the low installed capacity of existing heating units in China with maturely designed structure and control mode,and the low heating efficiency of newly built units with higher factors,the high pressure heating reformation plan of 300 MW Air Cooled Heat Supply Unit is brought forward.Through the analysis of operational factors and heating effect after the reformation,the plan proves feasible.Considers that the reformation plan is safe and economic,a reasonable trial to solve the heat supply in northern cities at the present stage.

High Pressure Heating Reformation of 300 MW Air Cooled Heat Supply Unit

Zhao Yan1,Feng Yun2

(1.China Huadian Corporation,Beijing 100031,China;2.Hebei Branch of China Huadian Corporation,Shijiazhuang 050000,China)

Key words:air cooled unit;high pressure heating;heat supply unit

2005年以前,国内的供热机组主要是50 MW、100 MW、200 MW抽汽凝汽机组,机组的结构设计及控制模式都比较成熟。随着近些年节能减排力度的不断加大,高耗能、污染严重的小火电逐步关停,部分城市尤其是北方城市的供热压力也随之增大,在不增加新建机组的前提下,对城市周边30 km范围内(最佳供热半径)的电厂进行供热改造成为现阶段解决此类问题的合理方案。300 MW机组在当前电网架构中,不再是系统的主力机组,对其进行供热改造,可以解决城市供热能力不足,降低机组的能耗水平,增加其在电力改革中的竞争力,为机组的生存与发展找出路。

1存在的问题

我国300 MW机组基本为一次中间再热机组,其热力系统相对较为复杂。常规情况下,300 MW机组供热改造基本是增加抽汽量,抽汽位置一般选在四段或是五段抽汽口。……