流式细胞仪与显微镜联合检测MRD的临床价值
2016-01-11李凤,蒲泽晏,刘方久等
流式细胞仪与显微镜联合检测MRD的临床价值*
李凤1蒲泽晏1刘方久2唐雪梅3魏容1梁艳丽1王欣3冯簏洁1
(遂宁市中心医院1.检验科,2.基础实验室,3.血液科, 四川 遂宁629000)
【摘要】目的了解流式细胞仪与显微镜联合检测微小残留白血病细胞(MRD)的临床价值。方法采集已确诊的白血病患者65例经化疗完全缓解(CR)后的骨髓,同时用四色多参数流式细胞仪和奥林巴斯显微镜做MRD检测共233次,检测急性白血病患者完全缓解后治疗过程中不同时间点的MRD。结果65例急性白血病患者诱导治疗缓解达CR后的233次MRD检测中,流式细胞仪MRD检测阳性率为55.4%(129/233例);显微镜FAB形态学方法检测阳性率为35.63%(83/233例)。流式细胞仪MRD监测的阳性率明显高于显微镜FAB形态学检测,两种方法结果比较,差异有统计学意义(P<0.01);233次MRD检测中59次显微镜形态学检测阴性而流式细胞仪检测阳性,13次显微镜检测阳性而流式细胞仪检测阴性。结论用四色多参数流式细胞仪能快速有效地对急性白血病患者进行MRD检测;用流式细胞仪与显微镜联合检测MRD,可避免因白血病细胞在治疗过程中某些标志丢失或改变而造成MRD假阴性,进一步提高MRD阳性检出率,对于提高急性白血病患者的生存率及生存质量和疗效评估及预后监测都具有重要意义。
【关键词】微小残留白血病细胞; 急性白血病; 流式细胞术; 显微镜
【中图分类号】R 446.8【文献标志码】A
基金项目:遂宁市科技计划项目(09M013)
收稿日期:( 2014-08-28; 编辑: 母存培)
Clinical application evaluation of MRD monitoring with flow cytometry and microscopeLI Feng1, PU Zeyan1, LIU Fangjiu2,etal
(1.ClinicalLaboratory,CentralHospitalofSuining,Suning629000,Sichuan;
2.BasicLaboratory,CentralHospitalofSuining,Suining629000,Sichuan;
3.DepartmentofHematology,CentralHospitalofSuining,Suining629000,Sichuan)
Abstract【】ObjectiveTo find the clinical value of the minimal residual disease (MRD) with flow cytometry and microscope. MethodsWe collected marrow from the 65 patients who complete remission after chemotherapy and detected the MRD levels for 223 times in the therapy progress with four-color multiparameter flow cytometry and OLYMPUS microscope. ResultsThe positive rate of MDR detected with flow cytometry was 55.4%(129/233). The positive rate of MDR detected with microscope was 35.63%(83/233). The positive rate of MDR detected with flow cytometry was significant higher than that detected with microscope. The difference was considered statistically significant(P<0.01). 59 cases were MDR position detected with flow cytometry but negative with microscope. 13 cases were MDR negative detected with flow cytometry but positive with microscope. ConclusionWith four-color multiparameter flow cytometry, we could monitor the MDR level of patients with acute leukemia quickly and effectively. United monitoring with flow cytometry and microscope could avoid the false negative because of biomarker change and improve the detection rate of MDR. It is meaningful for improving the survival rate and quality of life of patients with acute leukemia, evaluating of curative effect and monitoring the prognosis.
【Key words】Minimal residual disease; Acute leukemia; Flow cytometry; Microscope

1材料与方法
1.1一般资料选择我院血液科2012年1月1日~2013年12月31日住院的、经奥林巴斯显微镜FAB细胞形态学和细胞化学染色及四色流式细胞仪免疫学分型确诊为急性白血病患者65例,分别为AML-M1 4例、AML-M2 13例、AML-M3 15例、AML-M4 3例、AML-M5 12例、AML-M6 2例、ALL 16例,其中男39例,女26例,年龄3~75岁,平均35岁。在急性白血病化疗1个月经FAB诊断标准完全缓解后,分别在缓解期不同维持治疗期行骨髓复查时同时做流式细胞计数分析和显微镜FAB形态学MRD检查,总共233次。
1.2仪器和试剂所用仪器为美国BD公司生产的FACSCalibur四色多参数流式细胞仪和日本奥林巴斯公司生产的OLYMPUS BX51高清显微镜;……