摘 要:消防水泵相比普通离心泵而言,有一些特殊要求,为使工程设计人员能尽快掌握消防水泵的特点,根据实际工作经验,结合GB6245、NFPA20标准的要求,以及FM/UL认证的要求,总结了炼化装置中消防水泵选型时的注意事项,供工程设计人员参考使用。

关 键 词:消防水泵;注意事项;GB6245;NFPA20;FM/UL认证

中图分类号:TE 624 文献标识码: A 文章编号: 1671-0460(2015)07-1667-04

Analysis on Matters Needing Attention in Selection of Fire-Fighting Pumps for Refinery and Chemical Plants

WANG Xiao-peng1,JU Hai-Hua2

(1. China Huanqiu Contracting & Engineering Corporation, Beijing 100012, China;

2. Beijing Modern Vocational and Technical College, Beijing 101309, China)

Abstract: Fire fighting pump has special characteristics comparing with ordinary centrifugal pumps. In order to make the engineering designer know the characteristics, matters needing attention in selection of fire-fighting pumps for refinery and chemical plants were analyzed based on engineering experiences and the requirements of standard of GB6245, NFPA20, FM/UL certification.

Key words: Fire fighting pump; Matters needing attention; GB6245; NFPA20; FM/UL certified

煉化装置的物料一般为易燃易爆介质,一旦发生火灾,其危害性巨大。消防水泵是整个消防系统的“心脏”设备,因此消防水泵的选型就显得非常重要。作为一名工程设计人员,必须清楚相关标准规范对消防水泵的技术要求,笔者根据多年的工作经验,将工程设计阶段消防水泵选型的注意事项总结如下,供广大工程设计人员借鉴。

1炼化装置消防水泵的配置及适用标准

1.1 消防水泵的配置

根据消防水的来源不同,靠近海边的装置可能会采用海水消防泵,但大多数炼化装置中都是使用淡水消防泵。从驱动设备上看,一般是以柴油机驱动和电机驱动,理论上也可选用蒸汽透平等其他驱动机,但消防泵要求快速启动,蒸汽透平等其他驱动机往往不能满足要求,笔者执行过的项目中均为柴油机驱动和电机驱动。炼化装置中最为常见的配置是柴油消防泵+电动消防泵+电动保压泵,每种类型的台数的设置原则是在满足水量要求的前提下尽量减少台数,以减少泵房占地面积,同时要考虑适当的设置备用泵的数量。……