【摘要】考察了Ca(OH)2和CaCl2两种钙盐在反渗透浓水中的除氟效果。研究了Ca(OH)2和CaCl2除氟药剂投加量,合适的pH值,以及反渗透浓水中氯离子、硫酸根离子对除氟的干扰作用。试验结果表明:直接投加Ca(OH)2为3000 mg/L时或调节焦化反渗透浓水的pH值>9、CaCl2投加量为2000 mg/L时,出水氟离子低于10 mg/L,达到国家废水排放标准。
【关键词】焦化废水;反渗透浓水;除氟;钙盐
An Experimental Study on Defluorination of Reverse Osmosis Concentrated Coking Wastewater
Li Enchao, Yin Tingting
(Research Institute of Baoshan Iron & Steel Co., Ltd., Shanghai 201900, China)
【Abstract】The defluorinating effect of Ca(OH)2and CaCl2for reverse osmosis concentrated water was investigated and the addition dose, optimal pH value and interference of chloride ion in reverse osmosis concentrated water and sulfate ion on defluorination effect were studied. The experiment results indicated that when directly dosing 3000 mg/L of Ca(OH)2or adjusting the pH>9 of the concentrated water and directly dosing 2000 mg/L of CaCl2, the content of fluoride in outlet water was below 10 mg/L, meeting the requirement of national standard for wastewater discharge.
【Keywords】coking wastewater; reverse osmosis concentrated water; defluorination; calcium salt
1 引言
焦化废水是煤在高温干馏以及煤气净化、化学产品精制过程中形成的废水,其中含有酚、氨氮、氰、苯、吡啶、吲哚和喹啉等几十种污染物,成分复杂,有机污染物浓度及废水色度高、毒性大,性质非常稳定,是一种典型的难降解有机废水[1-2]。
从国内的焦化废水深度处理技术发展来看,切实可行的无二次污染的方法是采用反渗透技术将焦化废水深度处理后回用作为钢铁企业循环冷却用水,但存在的主要问题是反渗透产生的浓水的处理[3]。浓盐水的处理已经成为膜法深度处理技术应用的主要技术限制之一,同时也是钢铁焦化企业实现废水高回收率、废水零排放等目标需要解决的技术问题。浓水中不仅含有机污染物,而且也富集了氯离子、硫酸根离子和氟离子[4]。