针对移动通信基站电源线干扰现象,分析干扰信号的类型,把AC、DC线路干扰信号分别划分为8类和9类,设计了基站整机电源系统进行抗干扰能力的测试方法及测试装置。测试结果表明,抗干扰测试装置能够保证基站在多种注入式干扰或耦合干扰的情况下正常运行,验证了基站在过压、短时中断等应力环境下的工作能力,并保证基站在雷击等干扰下不被损坏,提高了对基站输入端口的抗干扰能力。
Power line disturbance exits in mobile communication base station. AC and DC line disturbance signals are categorized in 8 and 9 types respectively in order to analyze the type of disturbance signal. The test method and device of anti-disturbance capability for base station power system are designed. Test result states that such test setup can ensure the normal operation of the base station under the condition of multi injecting disturbance and coupling disturbance. It also verifies the performance of base stations under overvoltage and short interruptions and can ensure that the base station is not damaged in the lightning interference. Therefore this setup improves the anti-disturbance capability for the input port of base station.
anti-disturbance test design power port base station
1 引言
移动通信基站的发展已趋向多模化,支持多种通信调制方式。作为移动互联网的重要组成部分,基站广泛应用于各种地理环境,如城市、乡村、室内、室外、高原、湖泊、海洋船舶、旅游热点、高速铁路等,而基站工作的电源环境错综复杂,容易受到环境的干扰,包括交流/直流供电网络的切换、供电设备的波动、其它设备的信号串扰、自然界的雷雨天气甚至人为干扰。尽管网络中采用了不间断电源系统和辅助电源,但干扰仍然难以避免,所以基站电源的稳定工作尤为重要。基站电源在研发中的测试设计能够很好地保证电源的稳定性,从而保证基站系统的可靠性。
电源模块级测试注重功能性和负载能力,基站系统电源端口的测试则注重输入端口的阻抗特性对系统的影响以及系统的抗干扰能力[1-2]。电源线是内部电路暴露在机箱外面且与供电网络或其它设备连接部分,容易受到骚扰电压或骚扰电流,沿导线进入基站设备。……