APP下载

空腔式β射线粉尘测量仪的可行性研究

2014-08-26李宗伦彭丽婧李传琦

新媒体研究 2014年15期

李宗伦+彭丽婧+李传琦

摘 要 文章阐述了在粉尘浓度在线连续监测中发挥了独特优势的空腔式β射线粉尘测量技术的工作原理、系统结构及理论模拟结果,研究了空腔式β射线粉尘测量仪在粉尘监测中可能的使用效果,提出了研制测量仪的理论方案。

关键词 空腔;β射线;粉尘测量仪

中图分类号:TL81 文献标识码:B 文章编号:1671-7597(2014)15-0022-02

Feasibility study on dust measuring cavity instrument

based on β-ray

Zonglun Li1,Lijing Peng2,Chuanqi Li3

(1.School of Nuclear Science and Technology,University of South China,hengy 421001,China;2.Hunan Institute of Technology,Institute of Safty and Enviromental Enginneering,hengy 421002,China;3.School of Computer,University of South China,hengy 421001,China)

Abstract: This paper states the working principle, system structure and the theory simulation results of the cavity type beta-ray dust measurement technology which has an advantage in on-line continuous monitoring the concentration of dust , studies its possible effects on dust monitoring and puts forward the theoretical scheme of developing the measuring instrument.

Key words: Cavity;Beta ray;Dust measuring instrument

随着人类社会的发展及现代化工业的进步,大气中粉尘浓度的含量越来越高;特别是一些特殊行业的工作环境,有时甚至能达到危害工作人员身体健康的程度。因此,对大气中粉尘浓度进行监测已成为迫在眉睫的之事。然而,现阶段大气粉尘测量技术及仪器不能满足自动,实时数据连续测量(现阶段的粉尘测量仪多为滤膜式测量仪),无人操作及数据记录和传输的要求。为此,对空腔式β射线粉尘测量仪的技术开发进行了可行性研究。它可以实现连续自动监测大气中的粉尘浓度,并将数据记录储存。

1 仪器工作原理

强度恒定的β源发出的β射线通过介质时,β粒子与介质中的电子相互碰撞损失能量而被吸收。在低能条件下,吸收程度取决于介质的质量,与粉尘粒子的粒度、成分、颜色及分散状态等无关。吸收量与物质的质量关系为式(1):

(1)

式中:N为采样后被介质吸收后的β粒子计数;N0为采样前未经介质吸收的β粒子计数;μm为β粒子对特定介质的吸收系数(cm2/ mg);d为吸收介质的厚度(cm);ρ为介质的相对密度(mg/cm3)。

仪器的工作原理基于上式即应用β射线吸收技术来测量大气中粉尘的质量浓度。……