火电厂循环水处理方式的应用与研究
2012-10-19陈国忠
陈国忠
摘要:本文以330MW燃煤机组为例,结合内蒙古京科发电有限公司的水质特点,就火力发电厂中水量大,难处理的循环水的节能潜力进行了具体的分析,并对所实施的节能具体措施进行了论证。深层次剖析了水质变化对设备的影响,多角度全方位考虑合理确定了水处理的方式,为今后确保水资源的合理利用,为企业的节能降耗奠定了坚实的基础.
关键词:循环冷却水;腐蚀;结垢;节能
Abstract: Based on the 330MW coal-fired unit as an example, with the Inner Mongolia branch of Beijing Power Company Limited water quality characteristics, as in the power plant water treatment, circulating water saving potential are analyzed in detail, and the implementation of specific measures of energy saving are discussed. Deep analysis on water quality change of equipment, much angle is all-around consideration to determine the water processing method, for the future to ensure the rational use of water resource, for the enterprise energy saving and laid a solid foundation.
Key words:circulating cooling water; corrosion; scaling; energy saving
中图分类号:V444.3+7 文献标识码:A 文章编号:2095-2104(2012)
火力发电厂的循环冷却水系统,具有耗水量大,处理比较困难的特点,正由于其耗水量大,就必然要涉及到对水资源如何充分利用和水如何处理两大技术问题,这是一对相互矛盾的问题,因为要想少耗水,实现更大程度上的循环使用,必将导致很高的浓缩倍率,而为避免高浓缩水造成的含盐量大,可能引起设备系统结垢的问题,就必然要增大水的处理费用,所以,循环水的节能必须以用相对较少的费用实现最大限度地节约水资源为出发点,尤其是作为自治区节水型企业,合理利用水资源,是我们面临的一个十分重要的课题.
1、循环冷却水存在的问题
冷却水在循环使用过程中,水在冷却塔内和空气充分接触,使水中的溶解氧得到补充,所以循环水中溶解氧总是饱和的,水中溶解氧是造成金属电化学腐蚀的主要原因,这是冷却水循环使用后易带来的问题之一。
水在冷却塔中蒸发,使循环水中含盐量逐渐增加,加上水中二氧化碳在塔中解析逸散,使水中碳酸盐在传热面上结垢析出的倾向增加,这是问题第二。……