某宾馆大厅新建钢结构工程的加固设计
2012-10-15朱诚诚夏传琦
朱诚诚 夏传琦
摘 要:某宾馆的钢结构大厅因设计时构件截面选择不当等因素,对该结构重新进行了内力和位移验算。根据验算的结果,结合现场检测获得的材料及结构性能参数,对不满足要求的构件进行了加固设计。在各种加固方案对比的基础上,本工程采用体外预应力法加固构件,并对两种布索方案进行了详细的分析与比较,最终得出既满足要求又不影响结构使用功能要求的最为经济方便的加固方案。
关键词:结构加固设计;钢结构;框架结构;体外预应力
Abstract: Because of some hotel steel structure lobby component section inappropriate selection factors in the design, we redo the internal force and displacement calculation to the structure. According to the calculation results, combined with the material obtained and structural parameters components in the field testing, we do the reinforcement design of the component that is not meet the requirements. On the basis of the various reinforcement schemes comparison, this project adopts the external pre stressing reinforcement component, and analyzes in detail and compares these two kinds of cable schemes, and finally obtains the most economical and convenient reinforcement scheme which both meets the requirements and does not affect the structure use functional requirements.
Key words: structural reinforcement design; steel structure; frame structure; external pre stress
中圖分类号:TU391 文献标识码: A文章编号:2095-2104(2012)
1工程概况
某宾馆大厅的新建钢结构工程的主体结构为单层框架结构(如图1, 2 所示),长23.7m,宽7.3m。框架梁柱的钢材均采用Q345钢。框架柱与基础的连接采用刚接;框架柱与框架主梁的连接方式亦为刚性连接,各榀间的次梁与框架主梁两端铰接。由于业主对该工程没有足够的重视,没有进行严格的设计计算,生搬硬套其他工程的设计图纸,导致该工程尚未完工就已发现钢梁的挠度过大,影响了结构正常使用。由于原设计施工的结构不能满足正常使用的要求,因此必须按照《建筑结构荷载规范》[1]考虑结构的荷载,并且按照《钢结构设计规范》[2]
作者简介: 朱诚诚(1986-),男,江苏东台人,东南大学工学学士,
对结构进行校核及进行相应的加固处理。
图1单层框架结构立面布置图
2原框架结构分析
本文框架结构的分析主要借助于通用有限元分析软件SAP2000。
根据《建筑结构荷载规范》[1]并参考实际结构的使用情况,取钢结构大厅的楼面恒荷载为6.0、楼面活荷载为1.0。……