预应力混凝土管桩锤击施工技术的运用
2012-10-15冯立刚
冯立刚
摘要:预应力混凝土管桩(PHC桩),打桩前需做好桩锤、桩架选择,确定管桩龄期,打桩过程中插桩、锤打、接桩、送桩均采取了相应的技术措施。该工程中PHC桩所具有的单桩承载力高、桩身耐锤击性好、穿透力强、造价便宜等特点
关键词:预应力混凝土管桩, 单桩承载力, 锤击应力
Abstract: the prestressed concrete pipe pile (PHC), before piling need to be done to hammer, pile frames of choice, sure pipe), but the piling into piles, in the process of hammer, answer the pile, send pile are adopted corresponding technical measures. In this project is PHC pile of single pile bearing capacity of pile shaft and high resistance to hammer the gender is good, strong penetration, cost cheap and so on
Keywords: prestressed concrete pipe pile, single pile bearing capacity, hammer the stress
中图分类号:TU74 文献标识码:A文章编号:
1工程概况
某建筑为高层框架剪力墙结构,筏板基础,桩采用超高强预应力混凝土管桩,规格为ф600×110,桩长24m,共设93根桩,设计单桩承载力3100kN。
2打桩准备
2.1桩锤的选择
本工程有软、硬两种土层,选用蒸汽锤,锤重8t。
2.2桩架的选择
桩架的设置、安装和准备工作对打桩效率有很大影响。桩架选用D—308S型履带行走式桩架。
2.3桩帽、送桩器和衬垫的选择
1)桩帽和送桩器应做成与管桩直径匹配的圆筒形,桩帽的筒体深度取350~400mm,内径比管桩外径大20~30mm。筒式送桩器下端筒体深度取250~350 mm,内径比管桩外径大20~30 mm.
2)桩帽的送桩器的下端面应开孔,孔径不宜小于管桩1/5—1/3,确保管桩内腔与外界相通。
3)打桩时在桩锤与桩帽、桩帽、与桩顶之间应加设弹性衬垫,要求衬垫厚度均匀,经锤击后压实厚度不宜小于120㎜,且在打桩期间应经常检查,及时补充或更换。
2.4施工组织设计和桩位测设
根据打桩施工区域内的地质情况和基础几何形状,要合理选择打桩顺序,对周围建筑物采取预防措施。根据桩基施工图进行桩位测设。
2.5堆存吊运
管桩一般需设计两个支点,其吊点需符合位置要求。管桩堆存需要使用软垫(木垫)。……