【Abstract】With the protection of residential building construction, more and more choice of static pressure PHC pile for the pile foundation, significant savings in investment costs, and shorten the construction period, followed by new construction quality problems are more prominent.this article PHC hydrostatic pipe pile pile head crushing problem processing QC research, and successfully solve the problem, ensure that the affordable housing construction quality.
【Key words】PHC pile;Trailer coupling;Broken;Complete
1. 工程概况
嘉定保利家园二期桩基项目由我公司承建,施工内容为7幢楼的1197根PHCA400(80)-1212静压管桩(本文中均简称管桩),桩顶绝对标高为3.1m,地面绝对标高为8.2m。
2. 现状调查
从表1可以看出,影响桩头破碎的主要问题是管桩桩头质量得不到保证。由此,导致项目施工前期的管桩桩头破碎率达到6.06%。
3. 原因分析
管桩桩头质量的好坏直接影响压桩至设计桩顶标高的关键。
小组成员采用现场调查法对管桩桩头质量得不到保证的问题进行分析,并一一列举在因果图上(见图1):
3.1 施工人员操作经验不足。
操作人员为施工过程中主要人员,拉动和起吊管桩时,对管桩的合理处理、就位的准确性等操作控制不当将对管桩桩身质量产生破坏,本工程前期施工的198桩桩中有3节桩在拉动,起吊过程中管桩受折、受碰出现裂纹,无法使用。施工人员经验不足造成管桩桩头破碎的根数占总破碎根数的比例为25%。
从分析情况可以判断这是主要原因之一。
3.2 施工人员对管桩质量鉴别能力较低。
施工人员对管桩的质量合格与否,鉴别能力较低,厂家生产的管桩桩端和桩底强度均等,摆放顺序的颠倒不影响桩头的质量。……